RS485 ORP Sensor a ni
MTW-ORP7330 RS485 ORP Sensor hi tui quality enfiahna atana siam digital online redox potential sensor a ni.High-precision platinum measuring element-a siam a ni a, ORP value chu rang takin a man thei a, output nghet tak leh anti{6}}interference chak tak a nei bawk.
Automatic temperature compensation leh standard RS485 MODBUS-RTU digital communication a support a, PLC, DCS, data logger leh cloud monitoring system nena inzawm awlsam a ni.IP68 waterproof, corrosion-resistant leh anti-fouling structure hmangin, hun rei tak-term continuous online operation atan tui boruak khirh hrang hrangah a insiamrem thei a ni.
He RS485 ORP Sensor hi digital online oxidation-reduction potential probe a ni.Signal conversion leh temperature detection-a siam, high precision platinum sensing core.Output standard Modbus RTU protocol, plug and play, industrial water hrang hranga ORP monitoring chhunzawm zelna atana tha.


Technical lam chi hrang hrang (Typical) 1.1.
• A tehna hmun: -2000 mV atanga +2000 mV thleng.
• Electrode Material: A tlangpuiin platinum emaw rangkachak emaw thianghlimna sang tak a ni.
• Durability: A tam zawkah chuan IP68 waterproof rated a ni a, continuous immersion atan.
• Operating Temp: Standard sensor te hian 0–60℃atanga hna an thawk a, mahse specialized industrial model te chuan 130℃an thleng thei thung.
RS-485 Integration-a thatna pawimawh tak tak
• Digital Accuracy: Raw millivolt signal prone to thawn thin analog sensor hlui ang lo takin
• Long-Distance Transmission: RS-485 standard hian cable sei zawng zawnga data rintlak tak a thawn theih a ni
• Multi-Device Networking: A tlangpuiin pair khatah sensor 32 thleng connect theih a ni
• Internal Data Management: Model tam tak chuan calibration coefficient leh internal diagnostics te chu probe-ah direct-in an dah a, chu chuan system pumpui recalibrate lovin "plug-and-play" thlak theihna a siam a ni


Product Features te pawh a awm
1. RS-485 transmission interface, MODBUS-RTU inbiakpawhna protocol, bidirectional inbiakpawhna thlawptu.
2. Electrical himna tur atana power supply leh output design hrang hrang.
3. Anti-interference capability tihchak nan protection circuit siam-in, complex environment atan a tha.
4. Communication protocol awlsam leh user-friendly, intelligence sang zawk neih theihna turin electrode diagnostic information tam zawk output thei.
5. Low-power design hmanga hmanraw hrang hrang awm theihna tur; internal memory hian power outage laiin calibration leh settings a vawng reng thin.
6. PPS housing, corrosion resistance chak tak nei; 3/4-inch hma leh hnung thread hmanga dah awlsamna tur.
Industrial hmanna tlanglawn tak tak
• Disinfection Control: Swimming pool leh tui in tur-a chlorine emaw ozone emaw a that dan enfiah (disinfection atana ORP tha ber chu a tlangpuiin 650–750 mV a ni).
• Tui bawlhhlawh tihfai: Industrial effluent-a cyanide leh chromium ang chi bawlhhlawh paih chhuah dan control.
• Aquaculture: Oxygen-related redox state enfiah a, sanghate tui hrisel tak siam.
• Cooling Towers: Scaling leh biological growth ven nan chemical dosing automation

Technical Parameter hrang hrang te
|
ORP a ni |
A tehna Range |
-2000mV-2000mV inkar a ni |
|
|
Thutlukna |
1mV a ni |
||
|
Dik chiahna |
±1mV a ni |
||
|
Lum leh vawt tehna |
A tehna Range |
-10.0-110.0℃thleng a ni |
|
|
Thutlukna |
0.1℃a ni |
||
|
Dik chiahna |
±0.5℃a ni |
||
|
Sensor chi hrang hrang |
Thermistor TH10K hmanga siam a ni |
||
|
Compensation pek a ni |
Automatic/Manual hmanga tih theih a ni |
||
|
Data Inthlunzawmna |
RS-485 a ni |
MODBUS-RTU Inbiakpawhna Protocol |
|
|
Parameter dangte pawh a awm |
Power Supply a awm bawk |
9~27VDC a ni |
|
|
Isolation chakna |
2500Vrms a ni |
||
|
Power hman dan tur |
Approx0.5W vel a ni |
||
|
Bungrua |
PPSHousing tih a ni |
||
|
Mounting a ni |
3/4Inch Hma lam/Hnung lam Thread a ni |
Product hman dan tur








hot tags .: rs485 orp sensor, China rs485 orp sensor siamtute, factory