DPD Colorimetric Leh Electrochemical Methods: R Esidual Chlorine Analyzer Core Technologies te hi thuk taka zirchianna

Sep 08, 2026

Message pakhat dah la .

Tui quality himna enfiahna system-ah chuan residual chlorine analyser te hi hmanraw pawimawh tak angin an thawk a, tui in tur disinfection leh faina himna kawngah hmun pawimawh tak an chang a ni. Tunah hian industry-a detection technology hmante hi chi hnih-ah then a ni ber a, chungte chu DPD methods leh electrochemical methods te an ni. Heng technology pahnih hi detection principle hrang hranga siam a ni a, a dikna, a hman tangkai dan leh a hman theih tur scenario-ah te hian anmahni ziarang an nei vek a ni.

 

I. Technical Principles leh Detection Characteristics te

DPD Colorimetric hmanga thil tih dan

Detection Principle: Tui sample-ah DPD colorimetric reagent (N,N-diethyl-p-phenylenediamine) dahin residual chlorine chu redox reaction hmangin stable red compound a siam a. Wavelength bik (510nm)-a absorbance value chu spectrophotometer hmangin an teh a, chutah chuan residual chlorine concentration chu standard curve hmangin an chhut a ni. Hetiang hmang hian free chlorine (hypochlorous acid ang chi) leh total chlorine (combined chlorine pawh tel) awm zat chu a hranin a hriat theih a ni.

 

Core Advantages te chu:

  • Outstanding Analytical Accuracy: Detection limit chu 0.01 mg/L a thleng thei a, measurement error chu ±5% chhungah control a ni a, hei hian low-concentration residual chlorine dik taka analysis mamawhna a phuhruk a ni.
  • Anti-interference ability chak tak: Buffer solution leh masking agent dah belh hian tui sample-a common interfering substance (iron leh manganese ion ang chi) te nghawng chu a tha thei ang bera tihbo theih a ni a, chu chuan complex matrices nei tui sample hmuhchhuahna atan a tha hle.
  • Standard sang tak zawm: "HJ 586-2010 Tui Quality - Free leh Total Chlorine tehna - N,N-Diethyl-1,4-phenylenediamine Spectrophotometric Method" leh "GB 5749-2022 Standard for Drinking Water Quality" te technical requirements zawm kim vek.

 

A tihkhawtlai ber berte:

Reagent dependence: DPD reagent hi thlak fo a ngai a (shelf life hi thla 3-6 vel a ni tlangpui), chu chuan hun rei tak hmanna nen consumable cost a thlen thin.

Long detection cycle: Reagent dah belh atanga colorimetric stabilization thlengin minute 3-5 vel a ngai a, hei hian real-time monitoring mamawh a phuhruk thei lo.

 

Electrochemical hmanga thil tih dan

Detection mechanism: Detection system hi thil bik (platinum emaw gold electrode ang chi) atanga hnathawk electrode leh reference electrode atanga siam a ni. Residual chlorine hian electrode chung lamah electrochemical reaction a nei a, current signal a siam chhuak thin. Concentration chu current intensity emaw potential change emaw tehna hmanga quantified a ni. Mainstream technology-ah hian constant voltage electrolysis leh membrane-coated sensor technology te a tel a ni.

 

Core Advantages te chu:

Real-time Response: Data output hi electrode nena tui sample a inhnaih atanga second 30-60 chhungin a thleng a, hei hian online monitoring chhunzawm zel a siam thei a ni.

Maintenance Costs tlem: Consumable replacement neih fo a ngai lo; electrode dam chhung hi thla 6-12 vel a ni a, hun rei tak chhunga enkawl loha hnathawhna atan a tha.

Integrated Design: pH leh temperature ang chi parameter hrang hrang sensor te nen a inzawm thei a, parameter tam tak chu a rualin enfiah theih a ni.

 

A tihkhawtlai berte:

Environmental Sensitivity: Tui sample pH (optimal range 6.5-8.5), temperature inthlak danglamna (20-30℃-a control tura rawtna), leh organic matter concentration sang tak hian electrode drift a thlen thei.

Concentration hniam takah chuan Accuracy tling lo: Chlorine concentration awmsa a awm chuan<0.1mg/L, the relative error may exceed ±10%, requiring calibration at least once a week.

Inquiry thawn rawh .